Pure Sine wave 12v 220v solar inverter
Solar power inverter 1kw-3kw integrated MPPT charge controller
![1000W 2000W 3000W 4000W 5000W Solar Inverter](https://img.grofrom.com/renew/291eab77f1186caa7e322e174c237d0d.webp)
-- solar power inverter rated power: 1-3kw (off grid), higher power coming soon, and grid-tied units
-- solar power inverter, solar charger dc ac nominal: 12vdc/24vdc, 220vac, 110vac
-- home power inverter Ac charger: Max 70amp
-- solar power system, solar charge controller Pv charger(MPPT design): 45amp
-- solar system PV energy in priority for re-charge battery, or provide load in small load power
-- solar inverter with Ac charger will be activated when battery voltage low than 11vdc, ac will provide power for load
On condition that pv insufficient and battery exausted(10.3vdc per cell)
-- solar system Battery energy supply in priority means secure power backup solution.
Solar power system, solar inverter, solar power inverter, pure sine wave solar inverter enviromental, economic, power-saving application:
Home use for household electric appliance.
Solar battery charge controller specification:
Solar power inverter specification
Solar power inverter electrical view
Solar power inverter back view terminals block
Solar power inverter back view RS232 port
Solar power inverter battery cable accessory
Solar power inverter 1kw-3kw integrated MPPT charge controller
![1000W 2000W 3000W 4000W 5000W Solar Inverter](https://img.grofrom.com/renew/291eab77f1186caa7e322e174c237d0d.webp)
-- solar power inverter rated power: 1-3kw (off grid), higher power coming soon, and grid-tied units
-- solar power inverter, solar charger dc ac nominal: 12vdc/24vdc, 220vac, 110vac
-- home power inverter Ac charger: Max 70amp
-- solar power system, solar charge controller Pv charger(MPPT design): 45amp
-- solar system PV energy in priority for re-charge battery, or provide load in small load power
-- solar inverter with Ac charger will be activated when battery voltage low than 11vdc, ac will provide power for load
On condition that pv insufficient and battery exausted(10.3vdc per cell)
-- solar system Battery energy supply in priority means secure power backup solution.
Solar power system, solar inverter, solar power inverter, pure sine wave solar inverter enviromental, economic, power-saving application:
Home use for household electric appliance.
Solar battery charge controller specification:
Solar power inverter specification
Solar power inverter electrical view
Solar power inverter back view terminals block
Solar power inverter back view RS232 port
Solar power inverter battery cable accessory
Model | PV1012C | PV1024C | PV2012C | PV2024C | PV3012C | PV3024C |
Rated Output Power(W) | 1000 | 2000 | 3000 | |||
Line mode specifications | ||||||
Input Voltage | 12V | 24V | 12V | 24V | 12V | 24V |
Input Frequency | 50Hz@40-80Hz/60Hz@40-80Hz | |||||
Output Voltage Waveform | Pure Sine Wave | |||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||
Inverter Mode Specifications | ||||||
Output Voltage Waveform | Pure Sine Wave | |||||
Power Factor | 1 | |||||
Output Voltage (V) | 110Vac/120Vac/220Vac/230Vac ±10% | |||||
Output Frequency (Hz) | 60Hz ± 0.3Hz / 50Hz ± 0.3Hz | |||||
Auto Tracking Main Frequency | Yes (Following main first connection) 50Hz @40-80Hz 60Hz @40-80Hz | |||||
Output Voltage Regulation | ±10% rms | |||||
Efficiency | >80% | |||||
Over-Load Protection | (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150 ±10%: Fault (shutdown output) after 20s | |||||
Surge Rating | 3000VA | 6000VA | 9000VA | |||
Capable Of Starting Electric Motor | 1HP | 1HP | 2HP | |||
Inverter Breaker Size | 10A | 30A | ||||
DC Input Voltage | 12V | 24V | 12V | 24V | 12V | 24V |
Min DC Start Voltage | 11V/22V | |||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery 21.0Vdc ± 0.6Vdc for 24V battery | |||||
Low DC Input Shut-Down | 10.0Vdc ± 0.3Vdc for 12V battery 20.0Vdc ± 0.6Vdc for 24V battery | |||||
High DC Input Alarm & Fault | 16.0Vdc ± 0.3Vdc for 12V battery 32.0Vdc ± 0.6Vdc for 24V battery | |||||
High DC Input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery 31.0Vdc ± 0.6Vdc for 24V battery | |||||
Power Saver | Load ≤25W | |||||
Charger Mode Specifications | ||||||
Input Voltage | 110Vac/120Vac/220Vac/230Vac | |||||
Input Voltage Range | 96~127Vac/ 155~265Vac | |||||
Output Voltage | 110Vac/120Vac/220Vac/230Vac ±10% | |||||
Charge Current | ||||||
Charge Current Regulation | Charge Current Adjustable: 25%, 50%, 75%, 100%. (Optional) | |||||
Battery Initial Voltage | 0-15.7Vdc / 31.4Vdc (can operate with 0V battery) | |||||
Charger Short Circuit Protection | Circuit breaker | |||||
Over Charge Protection | Bat. V ≥15.7Vdc/ 31.4Vdc , beeps 0.5s every 1s & fault after 60s | |||||
General Specifications | ||||||
Certification | CE / ISO9001 | |||||
Operating Temperature Range | 0°Cto 40°C | |||||
Storage Temperature | -15°C to Sheet3!C3 | |||||
Operation Humidity | 5% to 95% | |||||
Audible Noise | 60dB max | |||||
Cooling | Forced air, variable speed fan | |||||
Size | 1012C / 1024C / 2012C / 2024C / 3012C / 3024C: 460x260x185MM | |||||
Gross Weight | 21KG | 26KG | 29.8KG | |||
MPPT solar controller function | ||||||
Rated voltage | 12/24V DC | |||||
Rated charge current | 40A | |||||
Load current | 15A | |||||
Input voltage range | 15-55V DC | |||||
Max. PV open circuit array voltage | 55V DC | |||||
Typical idle consumption | At idle< 10mA | |||||
Overload protection(DC load) | 2.0 * Inom>5s; 1.5 * Inom>20s; 1.25 * Inom temperature controlled | |||||
Bulk charge | 14.6V(default) | 29.2V(default) | ||||
Floating charge | 13.4V(default) | 26.8V(default) | ||||
Equalization charge | 14.0V(default) | 28.0V(default) | ||||
Over charge disconnection | 14.8V | 29.6V | ||||
Over charge recovery | 13.6V | 27.2V | ||||
Over discharge disconnection | 10.8V(default) | 21.6V(default) | ||||
Over discharge reconnection | 12.3V | 24.6V | ||||
Temperature compensation | 13.2mV/C | 26.4mV/C | ||||
Lead acid battery settings | Adjustable | |||||
NiCad battery settings | Adjustable | |||||
Load control mode | 1.Low Voltage Reconnect(LVR):Adjustable; 2.Low Voltage Disconnect(LVD):Automatic disconnection; 3.Reconnection:Includes warning flash before disconnect and reconnection | |||||
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc | ||||
low voltage disconnet | 10.5-12.5Vdc | 21.0-25.0Vdc | ||||
Ambient temperature | 0to 40°C(full load) 40-60°C(de-rating) | |||||
Altitude | Operating5000m, Non-Operating 16000m | |||||
Protection class | IP21 | |||||
Battery temperature sensor | BTS-optional remote battery temperature sensor for increased charging precision | |||||
Terminal size(fine/single wire) | #8 AWG |